Model AW
|
|
60
|
100
|
130
|
200
|
260
|
|
Koelcapaciteit*
|
KW
|
65
|
97.5
|
130
|
195
|
260
|
|
Ingang koelvermogen
|
KW
|
20.8
|
31.4
|
42.1
|
63.6
|
84.2
|
|
Verwarmingscapaciteit **
|
KW
|
68
|
102
|
136
|
204
|
272
|
|
Opgenomen vermogen verwarming
|
KW
|
20.2
|
30.6
|
41
|
61.2
|
82
|
|
Max. Ingangsvermogen
|
KW
|
24
|
35.7
|
47.7
|
71.4
|
95.4
|
|
Max. Ingangsstroom
|
A
|
50
|
74
|
97
|
148
|
194
|
|
Bedrijfsstroom koeling
|
A
|
46
|
68
|
89
|
136
|
178
|
|
Startstroom
|
A
|
167
|
187
|
206
|
374
|
412
|
|
Compressor
|
|
Voeding
|
/
|
380/3/50
|
|
Merk/Type
|
/
|
Daikin/scrollen
|
|
Koelmiddel
|
/
|
R410A
|
|
Hoeveelheid/koelmiddelcircuit
|
Nr.
|
2
|
3
|
4
|
6
|
8
|
|
Ingang koelvermogen*
|
KW
|
2*9.4
|
3*9.63
|
4*9.77
|
6*9.63
|
8*9.77
|
|
Ingang verwarmingsvermogen**
|
KW
|
2*9.1
|
3*9.36
|
4*9.5
|
6*9.36
|
8*9.5
|
|
Energieaanpassing
|
%
|
0-25-50-75-100
|
|
Axiale Ventilator
|
|
Hoeveelheid
|
Nr.
|
2
|
2
|
2
|
4
|
4
|
|
Opgenomen vermogen
|
KW
|
2
|
2.5
|
3
|
5
|
6
|
|
Luchtstroom
|
m3
/u
|
24000
|
36000
|
48000
|
72000
|
96000
|
|
Verdamper
|
|
Type
|
/
|
Shell- en tube -warmtewisselaar
|
|
Waterstroming Tijdens het koelen
|
m3
/u
|
11.2
|
16.8
|
22.4
|
33.6
|
44.8
|
|
Waterstroming Tijdens het verwarmen
|
m3
/u
|
11.7
|
17.6
|
23.4
|
35.1
|
46.8
|
|
Drukval waterzijde ***
|
KPa
|
46
|
52
|
55
|
52
|
55
|
|
Grootte van de wateraansluiting
|
DN
|
50
|
50
|
65
|
2 x 50
|
2 x 65
|
|
Geluidsniveau***
|
|
DB(A)
|
70
|
72
|
72
|
74
|
75
|
|
Afmetingen
|
|
|
Spoel van het V-type
|
Lengte
|
mm
|
2000
|
2207
|
2207
|
2207
|
2207
|
|
Breedte
|
mm
|
1060
|
1300
|
1300
|
2207
|
2207
|
|
Hoogte
|
mm
|
1957
|
2076
|
2076
|
2096
|
2096
|
|
Nettogewicht
|
|
kg
|
620
|
1060
|
1120
|
2160
|
2280
|
|
Werkgewicht
|
|
kg
|
635
|
1090
|
1155
|
2220
|
2350
|