| Model | YXEL-225 | YXEL-480 | YXEL-600 | YXEL-800 | YXEL-1200 |
| Inner size(W*H*D)mm | 500*700*600 | 800*1000*600 | 800*900*850 | 900*900*900 | 1000*1200*1000 |
| Xenon lamp power(Kw) | 2.2 KW air cooling type,3.3/4.5KW water cooling type | ||||
| Temperature range | RT+10ºC~90ºC | ||||
| Black Panel Temperature | 40-110ºC | ||||
| Humidity range (light) | 10%~70%R.H | ||||
| Humidity range (dark) | 10%~95%R.H | ||||
| Accuracy range | Temperature±0.1 humidity±1%R.H | ||||
| Rainfall time | 1~9999h/59min adgustable | ||||
| Rainfall cycle | 1~9999h/59min adgustable | ||||
| Water supply system | Bring filter,Automatic control by humidifying water. Cooling water loop xenon lamp | ||||
| Wave length | 200nm~800nm | ||||
| Irradiation capability | 200W/~800W/(adjustable) | ||||
| Irradiance deviation | ±0.1 W/m2 | ||||
| Temperature controller | Imported weinview color touch screen and PLC control module Siemens Germany | ||||
| Temperature and humidity sensor | Platinum resistance.PT100Ω/MV | ||||
| Sample holder | Automatic rotary rack | ||||
| Materail | SUS304 stainless steel plate | ||||
| Door insulation | High temperature aging silicone rubber door seal | ||||
| Safety protection |
Leakage, short circuit, over temperature, water shortage,
motor overheating, over current protection |
||||
| Test standards | Complies with JISD0205-1987,GB/T16422.2-1999,ISO4892-2,ASTMG155 GB/T1865-2009 GB/T2423.24-1995 and corresponding standards. | ||||
| Supply voltage | AC380V±10% 50±0.5Hz Three phase five wire system Phase | ||||